Technical guides
A wire-cut feature can meet its dimensions and roughness while a drawing requirement for the surface layer remains open. Identify the finished feature and ask for separate evidence for each requirement before accepting the first article.

Technical guides
Two reports may both give a hydrogen value for the oxygen stream but describe different samples or reporting bases. Ask the issuers to align the test object, sample reference and operating condition before using the figures for acceptance.

Technical guides
Two titanium blanks can share a heat number and have different orientations after cutting. Tie the mother-plate direction to the approved layout and the delivered piece IDs before releasing parts that have a direction requirement.